011 284 2000 kipor@smithpower.co.za

IG2600 – 2.3kVA

Overview

  • Rated Power of 2.3kVA
  • Single-Phase
  • Rated Frequency 50 60Hz
  • Rated Voltage 230 120/240V
  • Smart throttle technology
  • Automotive unleaded Petrol-fuel type
  • Dry weight of 29.5Kg

Features

  • Unique Construction Utilizing the Latest Technology
  • Digital Petrol Generator
  • Pure Sine wave-Power System
  • Quality Power

GET A QUOTE

Model KDE12STA3
Rated frequency (Hz) 50
Rated output (kVA) 10
Max. output (kVA) 11
Rated Voltage (V) 230/400
Rated current (A) 14.5
Rated rotation speed (r/min) 3000
Phase NO. Three-phase, Y connection
Power factor (Cos Φ) 0.8(lag)
Insulation Grade B
Pole number 2
Excitation mode Self-excitation & constant voltage (AVR)
Panel Type Digital Panel
Voltage (V) 230/400 240/416
Receptacle Two single phase receptacles
Connection pole With
DC12V output Without
Overall dimension(L×W×H)(mm) 1350X795X850 1350X650X760(without wheels)
Dry weight(kg) 310
Working assorting weight (Kg) 345
Noise level(7m)dB(A) 72
Structure type Super Silent
Engine Model KM2V80G
Engine Type Two-cylinder, v-twin, water-cooled, four-stroke, swirl chamber
Cylinder NO.-bore×stroke (mm) 2-80×79
Displacement (ml) 794
Rated power [KW/(r/min)] 12.5/3000
Compression ratio 23:1
Rated rotation speed (r/min) 3000
Combustion system
Cooling system Water cooled
Lubrication system Pressure splashed
Starting system Electric starter
Fuel type diesel
Lube oil brand 15W-40
Capacity of cooling water (L) 3.5
Lube capacity (L) 2.27
Starting motor capacity (V-kW) 12V 1.4kW
Charging generator capacity (V-A) 12V 20A
Battery capacity (V-Ah) 12V 36Ah
Fuel consumption (g/kW.h) ≤340
Fuel tank capacity (L) 26
Continuous running time (hr) 7

Strong PowerAll generator sets are equipped with KIPOR four-stroke engines.Low Noise RunningHigh effective combustion system ensures complete combustion, Besides, a large silencer dampens exhaust noise and engine sounds which are contained by a double-wall structure and absorbed by a liner.Digital Control PanelAll the control units of the generator sets are on one panel, a monitor of the panel will display the real-time working data of the generator set such as its output voltage and current etc. Besides, the running trouble of the generator will also be displayed on the panel.Low Oil Alarm SystemBefore the oil level drops to the limited level, the generator set will stop automatically. The whole set can be restarted only if the oil is refilled.Application of New AVRThe AVR (Automatic Voltage Regulator) not only can smooth the output but also can provide reasonable protection against the overload of the whole set, thus avoid damage to the set.Advanced Alternator WindingWaveform distortion is kept at a minimum level and the output is stable. The winding design protects the generator from short circuits and provides a stable output while running inductive loads.ATS (Automatic Transfer Switch)On the inheriting of the original general-purpose generator set, KIPOR diesel generator sets with digital control panel can be equipped with a made ATS(automatic transfer switch). ATS, in its preset intervals, can automatically check and monitor the running of the genset to ensure the genset in good working condition. Meanwhile, ATS will monitor the utility power, if utility power fails or the voltage and frequency of the utility power become abnormal, ATS will give commands to start the genset automatically.