011 284 2000 kipor@smithpower.co.za

KDE35SS3 – 28kVA

Overview

  • Rated output of 28- MAX 35kVa
  • Rated Frequency of 50-60Hz
  • Generator model KFS30
  • Pole number 4
  • Three-phase, four-line and Y-connection loop mode

Features

  • More Powerful Performance
  • Automatic, Hands-off Operation
  • Safer Power for Sensitive Electronics
  • Quieter Operation
  • Meets Environmental requirements
  • Faster Response

GET A QUOTE

Model KGE12E
Rated frequency (Hz) 50
Rated output (kVA) 8.5
Max. output (kVA) 9.5
Rated Voltage (V) 230
Rated current (A) 36.9
Rated rotation speed (r/min) 3000
Phase NO. Single phase
Power factor (Cos Φ) 1.0
Insulation Grade B
Pole number 2
Excitation mode Self-excitation & constant voltage (AVR)
Panel Type General Panel
Voltage (V) 230
Receptacle Two receptacles
Connection pole With
DC12V output Without
Overall dimension(L×W×H)(mm) 910X600X760 910X600X620(without wheels)
Dry weight(kg) 161
Working assorting weight (Kg) 175  182
Noise level(7m)dB(A) 77
Structure type Open frame
Engine Model KG690
Engine Type Two-cylinder, air-cooled, four-stroke, V-twin, four-stroke,OHV
Cylinder NO.-bore×stroke (mm) 2-78×72
Displacement (ml) 688
Rated power [KW/(r/min)] 12.0/3000 14.0/3600
Compression ratio 8.5:1
Rated rotation speed (r/min) 3000 3600
Combustion system T.C.I
Cooling system Air cooled
Lubrication system Pressure splash
Starting system Electric starter
Fuel type Automatic unleaded gasoline
Lube oil brand CD grade or SAE10W-30,15W-40
Capacity of cooling water (L) Without
Lube capacity (L) 1.3
Starting motor capacity (V-kW) 12V 1.4kW
Charging generator capacity (V-A) 12V 8A
Battery capacity (V-Ah) 12V 36Ah
Fuel consumption (g/kW.h) ≤370
Fuel tank capacity (L) 25
Continuous running time (hr) 5

Digital Control PanelThe new gasoline genset model is equipped with digital control system and remote control. Some control units of the generator sets are on the multi function display.Real-time Data DisplayA monitor of the panel will display the real-time working data of the generator set such as its output voltage, Frequency, running time, battery voltage etc. Besides, the running trouble of the generator will also be displayed on the panel.Low Oil Alarm SystemBefore the oil level drops to the limited level, the generator set will top automatically. The whole set can be restarted only if the oil is refilled.New AVRThe AVR (Automatic Voltage Regulator) not only can smooth the output but also can provide reasonable protection against the overload of the whole set, thus avoid damage to the set.Electrical starterA convenient electric starter gets the new gasoline generator up and running quickly.